Service Manual
Third edition, June 1997
Temp 1, 2 or 3 in liq. This box is checked when this
temperature sensor is immersed in the liquid, when it
has stabilized and when the ullage value is valid.
The following database data are shown and can be changed:
L3, L2 or L1 type/range. This value shows if it is a
three-wire or four-wire type sensor that is used. The
temperature range is also defined by this value. The
following values can be shown:
• 0 for no connected temperature sensor.
• 1 for four-wire sensor with temperature range 0 to
+100°C.
• 2 for four-wire sensor with temperature range -50 to
+250°C.
• 5 for three-wire sensor with temperature range 0 to
+100°C.
• 6 for three-wire sensor with temperature range -50 to
+250°C.
H distance. The H distance is explained in the Installa-
tion Manual.
Any changes of the database values must be followed by
hitting the Save-button as well as restarting the transmitter
by hitting the Restart TX-button.